The short answer

  • What it is. A 155-page code for building, maintaining and renovating tunnels and shafts in NSW, approved under section 274 of the NSW Work Health and Safety Act 2011. It replaces the 2006 code. It does not cover mines and quarries.
  • Why it binds. Under section 26A of the NSW Act, a business must follow an approved code or another method that gives an equivalent or higher standard. The code says the word ‘should’ is used to identify the standard required in this Code. We explained what that change means in August.
  • What changes on silica. Operator cabins built to a named standard, no dry sweeping or compressed air on silica dust, a written occupational health and hygiene plan that names a certified hygienist and states how often air is monitored, and respirators with a protection factor of at least 50.
  • What it did not do. It does not require powered air-purifying respirators on every tunnel job, and it sets no tunnelling-specific silica limit. The national limit, 0.05 mg/m³, still applies.
  • First enforcement. SafeWork NSW says its inspectors visited three tunnel projects between late September and early November and issued five improvement notices.

Exhibit A · from the source

This Code of practice commenced on 28 August 2026. It replaces the 2006 Tunnels and shafts in construction Code of Practice.

The word ‘should’ is used to identify the standard required in this Code. PCBUs can only manage the identified hazard or risk in a different way if doing so provides an equivalent or higher standard of work health and safety than the standard required in this Code.

Transcribed from SafeWork NSW’s Tunnels and shafts in construction code of practice (August 2026), page 2 (editorial note) and page 9 (foreword), downloaded 21 November 2026. The wording is SafeWork NSW’s; the marking is ours. A PCBU is a person conducting a business or undertaking, the legal term for a business that holds the safety duty. Back to the summary

Twelve weeks in force before it was announced

The code was gazetted and took effect on 28 August. The ministerial release that put it on SafeWork NSW’s news page is dated 18 November, 82 days later. In it the Minister for Work Health and Safety, Sophie Cotsis, says This is the first time in 20 years the tunnelling code of practice has been updated, and it is now a legally enforceable minimum standard that must be complied with.

The release also reports a first round of checks: Inspectors visited three tunnel projects during the operation and issued five improvement notices. It does not say what the notices were for. Across all industries, it says, since 1 July 2024 inspectors have made more than 4,156 silica-related visits and issued 2,063 improvement notices, 520 prohibition notices and 73 penalty notices.

The code was also later than planned. In its September 2025 response to the parliamentary review, the NSW Government said of the rewrite: This work is scheduled for completion by the end of 2025. It commenced 240 days after that date.

What the committee asked for, and what the code does

The review was run by the NSW Legislative Council’s Standing Committee on Law and Justice, the upper-house committee that reviews the dust diseases compensation scheme. Its report, tabled on 20 June 2025, made 26 recommendations. Four go to how silica is controlled in tunnels.

Exhibit B · from the source

That SafeWork NSW update the Code of Practice for Tunnels Under Construction to include the mandatory use of Powered Air Purifying Respirators in all tunnelling projects.

That the NSW Government consider lowering the workplace exposure standard for respirable crystalline silica to 0.025 mg/m3 in the tunnelling industry to better protect workers.

That SafeWork NSW takes measures to include specific requirements for air monitoring for respirable crystalline silica in the Code of Practice for Tunnels Under Construction

That the NSW Government consider introducing statutory roles for certified occupational hygienists and ventilation officers for tunnelling projects

Transcribed from the summary of recommendations (pages xi and xii) of Report 86, 2024 Review of the Dust Diseases Scheme (June 2025), downloaded 21 November 2026. In order: recommendations 14, 16, 17 and 18. The last two continue past the words shown; the marking is ours. Back to the summary
The committee’s four tunnelling recommendations, the government’s response, and what the August 2026 code says
AskGovernment response (Sept 2025)What the code doesOur verdict
14. Powered air-purifying respirators mandatory on all tunnel jobsNotedNo blanket requirement. Underground workers should have respirators with a protection factor of at least 50 (p 128). Powered respirators are named as typical for underground welding (p 97) and as the option for workers with facial hair (p 127)Not adopted
16. Silica limit of 0.025 mg/m³ for tunnellingSupported in principle, subject to national consistencyNo tunnelling-specific number anywhere in the code; it refers to the national list (p 101)Not adopted
17. Specific air monitoring requirements for silicaNotedA risk-based monitoring program to a recognised method such as EN 689, samples analysed by an accredited laboratory, exposure groups set by a competent person such as a hygienist, continuous real-time monitoring with alarms (pp 99 to 102). No fixed frequencyPartly adopted
18. Statutory roles for certified hygienists and ventilation officersSupported in principleThe hygiene plan should name the hygienist (p 35), defined as a certified occupational hygienist (p 134). A ventilation officer is defined (p 137) but no project is told to appoint onePartly adopted, not statutory

Recommendations from the committee’s report; responses from the government response tabled 11 September 2025 (pages 11 to 13); code page numbers are the code’s own. The verdict column is our reading. A code cannot create a statutory role, so recommendation 18 could only ever be partly met by a code.

On the lower limit, the government said it will consider this recommendation in line with NSW’s commitment to adopting and maintaining nationally consistent Work Health and Safety (WHS) laws. Nationally, ministers did not agree in June to halve the silica limit, so the November 2026 workplace exposure limits list that takes effect on 1 December carries quartz at 0.05 mg/m³, as an eight-hour average. We reported that decision in July. Safe Work Australia, the national body that writes the model laws, said on 29 October that silica and the seven other chemicals still undecided are with an independent expert panel (our report).

What a tunnelling contractor now has to meet on silica

The code repeats the legal duties already in the NSW regulation, such as the silica risk control plan and the duty to send SafeWork NSW any silica air monitoring result above the exposure standard no more than 14 days from the date that the air monitoring result was reported to the PCBU. What section 26A changes is the force of the code’s “should” lines: each is now the standard. The ones most likely to show on a site:

  • Cabins. Where the emission of RCS arises from the operation of an excavator, roadheader or other machine, the operator of that machine should be protected by an enclosed cabin that meets the requirements of AS/NZS ISO 23875:2023. That is the standard for pressurised, filtered operator cabins (p 110). RCS is respirable crystalline silica, the fine dust that causes silicosis.
  • Cleaning. Dry sweeping, the use of compressed air or blowers, and high-pressure water blasters should not be used to remove dusts that may contain RCS. Wet methods or M- or H-class vacuums instead, and decontamination and laundry facilities for workers (p 111).
  • A written hygiene plan. all tunnel projects should develop an occupational health and hygiene plan, with 18 minimum contents, among them the nominated hygienist, trigger action response plans and the minimum frequency of exposure/air monitoring (pp 35 to 36).
  • Respirators. Underground workers should be provided with RPE that has a minimum protection factor of 50, unless a risk assessment involving an Occupational Hygienist determines that a different level of protection is appropriate. Tight-fitting masks need annual quantitative fit testing (pp 127 to 128).
  • Real-time dust monitors. Where they are used, the hygienist should set and document the factor that converts a dust reading into a silica estimate, based on the material being cut (p 113).
  • Health checks. Chest X-rays read by a B reader, a radiologist trained to detect dust lung disease, or an equivalently trained radiologist, with high-resolution CT as a possible alternative (p 114).

Our read

This section is opinion, built on the documents cited above.

This is a real tightening, and section 26A is why. Before 1 July 2026 a “should” line on operator cabins was advice a court could weigh afterwards. Now it is the standard, and a contractor that does something else has to show its method is at least as good. Several of these lines, the cabin standard, the ban on dry sweeping and the certified hygienist, are concrete enough to check on a site visit.

On respirators, the code chose a performance floor rather than a device, and we think that is defensible. A protection factor of 50 applies to whatever is worn, and the code itself points bearded workers to loose-fitting powered respirators. The weak spot is the exit: the floor gives way wherever a risk assessment involving a hygienist decides that a different level is appropriate. An inspector asking to see that assessment is the check that keeps the exit narrow.

Monitoring is where the committee’s word was “consistency”, and the code does not deliver it by itself. It requires every project to write down how often it monitors, but each project sets its own number. Whether that produces consistent results can be measured, because SafeWork NSW already receives every silica result above the exposure standard within 14 days. The release counts visits and notices; it gives no count of those results from tunnels. That count is the honest test of whether this code is working, and SafeWork NSW should publish it. We asked SafeWork NSW on 21 November 2026 how many such notifications it has received from tunnel projects and whether it will publish the figure, and will add its answer here, or say if none arrives.

Methodology

We found the 18 November release on SafeWork NSW’s news listing, rendered in a browser on 21 November 2026, and downloaded the code (155 pages) from SafeWork NSW’s list of WHS codes of practice, where it is dated August 2026. We read the code’s chapters on health (5), air quality (17), silica (19) and protective equipment (23), its foreword and glossary, and searched all 155 pages for “0.025”, “0.05” and “PAPR”: neither number appears, and powered respirators appear only on pages 97 and 127. We read the committee’s recommendations and the government’s response to all 26, and searched the release for any count of exceedances: there is none. Arithmetic: 28 August to 18 November 2026 is 82 days (3 days left in August, 30 in September, 31 in October, 18 in November); 31 December 2025 to 28 August 2026 is 240 days (31 + 28 + 31 + 30 + 31 + 30 + 31 + 28). Quotations are verbatim from the source linked beside them.